  Datasheet File OCR Text:
  luxeon k delivers high fux at high efcacy in a small, easy-to-u se package. the high lumen density enables high light output in th ermally and space constrained systems (like retroft lamps) and high efc iency in systems aiming for high energy efciency (such as downlights). t he small size bolt-down package enables simple assembly in space constra ined systems. with freedom from binning , every luxeon k white product falls within a single 3-step macadam ellipse positioned around the ce nter point of the ansi nominal cct bins to deliver tight cct control to ensure consistency in system color point. in addition, these parts del iver the lumen maintenance and reliability that all luxeon leds are renowned for. luxeon k plug and play matrix platform solution with precise fux, v f and color features and benefits primary applications 300C5000 lumen packages for a range of options downlights 3-step macadam ellipse color binning for exceptional lamp to lamp consistency lamps l2 design for a reduction in design costs full range of ccts and cris including royal blue lm-80 test report available for new designs consider this replacement product: ? luxeon cob core range (gen 3) illumination DS102 luxeon k product datasheet ?2016 lumileds holding b.v. all rights reserved. rohs compliant no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. i table of contents general information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 product nomenclature ................................................................................... 2 average lumen maintenance characteristics .............................................................. 2 environmental compliance ............................................................................... 2 product selection ........................................................................................... 3 optical characteristics ....................................................................................... 5 electrical characteristics ..................................................................................... 6 absolute maximum ratings .............................................................................. 7 electrical lead soldering characteristics ................................................................... 7 mechanical dimensions ..................................................................................... 8 relative spectral distribution vs. wavelength characteristics ................................................... 15 light output characteristics over temperature ................................................................ 16 typical forward current characteristics ...................................................................... 17 typical radiation patterns .................................................................................. 23 packaging on trays ......................................................................................... 23 luxeon k white ansi color bin defnition .................................................................. 26 no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 2 general information product nomenclature luxeon k products are specifed and binned hot (t j = 85c) under conditions comparable to those found in real-world lighting products. the part number designation is explained as follows: l x k a - p b c d - e f g h j where: a designates minimum cri performance (value 8 = 80 minimum, value 9 = 90 minimum, value 0 for royal blue) b designates color (value w = white, value r = royal blue) c, d designates nominal ansi cct (value 27 = 2700k, 30 = 3000k, 35 = 3500k, 40 = 4000k, 50 = 5000k, and 04 = royal blue 447.5nm - 452.5nm peak wavelength) e, f custom spec designation or multi-junction designation (f - number of strings, h number of emitters, for example 0206, 2 strings of 3 = total emitters of 6) g, h emitter count j denotes a fux upgrade (e.g, a, b, c, etc) therefore, 3000k products specifed at 350ma 85c follow the part numbering scheme: l x k 8 - p w 3 0 - 0 0 0 4 for luxeon k white 3000k 4-up l x k 8 - p w 3 0 - 0 0 0 8 for luxeon k white 3000k 8-up l x k 0 - p r 0 4 - 0 0 0 8 for luxeon k royal blue 8-up average lumen maintenance characteristics lumen maintenance for solid-state lighting devices (leds) is typically defned in terms of the percentage of initial light output remaining after a specifed period of time. lumileds projects that luxeon k products will deliver, on average, 70% lumen maintenance (l70) at 50,000 hours of operation at a forward current of up to 700ma. this projection is based on constant current operation with junction temperature maintained at or below 125c. this performance is based on independent test data, lumileds historical data from tests run on similar material systems, and internal luxeon reliability testing. observation of design limits included in this data sheet is required in order to achieve this projected lumen maintenance. environmental compliance lumileds is committed to providing environmentally friendly products to the solid-state lighting market. luxeon k is compliant to the european union directives on the restriction of hazardous substances in electronic equipment, namely the rohs directive. lumileds will not intentionally add the following restricted materials to the luxeon k: lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (pbb) or polybrominated diphenyl ethers (pbde). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 3 product selection product selection guide for luxeon k white, junction temperature = 85c table 1. nominal cct emitter count part number test current (ma) minimum cri typical cri minimum flux (lm) typical flux (lm) maximum flux (lm) 2700 * 3 lxk8-pw27-0403 87.5 80 83 270 285 320 2700 4 lxk8-pw27-0004a 350 80 83 360 400 430 2700 * 4 lxk8-pw27-0404 87.5 80 83 340 355 410 2700 * 6 lxk8-pw27-0206 175 80 83 530 600 670 2700 8 lxk8-pw27-0008a 350 80 83 730 765 870 2700 12 lxk8-pw27-0012a 350 80 83 1100 1150 1320 2700 16 lxk8-pw27-0016a 350 80 83 1480 1530 1770 2700 24 lxk8-pw27-0024a 350 80 83 2230 2380 2670 3000 * 3 lxk8-pw30-0403 87.5 80 83 270 285 320 3000 4 lxk8-pw30-0004a 350 80 83 380 460 510 3000 * 4 lxk8-pw30-0404 87.5 80 83 355 375 420 3000 * 6 lxk8-pw30-0206 175 80 83 540 620 690 3000 8 lxk8-pw30-0008a 350 80 83 760 920 1030 3000 12 lxk8-pw30-0012a 350 80 83 1140 1375 1530 3000 16 lxk8-pw30-0016a 350 80 83 1520 1640 1870 3000 24 lxk8-pw30-0024a 350 80 83 2280 2485 2820 3500 4 lxk8-pw35-0004 350 80 83 400 470 530 3500 8 lxk8-pw35-0008 350 80 83 820 920 1040 3500 12 lxk8-pw35-0012 350 80 83 1200 1360 1540 3500 16 lxk8-pw35-0016 350 80 83 1590 1750 1980 3500 24 lxk8-pw35-0024 350 80 83 2420 2750 3100 4000 * 3 lxk8-pw40-0403 87.5 80 83 310 325 370 4000 4 lxk8-pw40-0004a 350 80 83 420 505 560 4000 * 4 lxk8-pw40-0404 87.5 80 83 410 430 490 4000 * 6 lxk8-pw40-0206 175 80 83 625 740 820 4000 8 lxk8-pw40-0008a 350 80 83 820 1000 1100 4000 12 lxk8-pw40-0012a 350 80 83 1250 1405 1590 4000 16 lxk8-pw40-0016a 350 80 83 1680 1875 2120 4000 24 lxk8-pw40-0024a 350 80 83 2530 2860 3230 5000k 4 lxk8-pw50-0004 350 80 83 440 530 600 5000k 6 lxk8-pw50-0206 350 80 83 670 735 820 5000k 8 lxk8-pw50-0008 350 80 83 890 1075 1100 5000k 12 lxk8-pw50-0012 350 80 83 1310 1605 1790 5000k 16 lxk8-pw50-0016 350 80 83 1760 2070 2180 5000k 24 lxk8-pw50-0024 350 80 83 2650 3255 3230 table 1 continued on page 4. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 4 table 1 continued. nominal cct emitter count part number test current (ma) minimum cri typical cri minimum flux (lm) typical flux (lm) maximum flux (lm) 3000 8 lxk7-pw30-0008 350 70 73 1020 1070 1225 3000 12 lxk7-pw30-0012 350 70 73 1490 1565 1785 3000 16 lxk7-pw30-0016 350 70 73 2005 2105 2405 4000 8 lxk7-pw40-0008 350 70 73 1020 1070 1225 4000 12 lxk7-pw40-0012 350 70 73 1560 1635 1870 4000 16 lxk7-pw40-0016 350 70 73 2040 2150 2445 2700 4 lxk9-pw27-0004 350 90 93 300 315 360 2700 8 lxk9-pw27-0008 350 90 93 610 640 730 2700 12 lxk9-pw27-0012 350 90 93 940 985 1120 2700 16 lxk9-pw27-0016 350 90 93 1265 1330 1510 2700 24 lxk9-pw27-0024 350 90 93 1880 1975 2250 3000 4 lxk9-pw30-0004 350 90 93 320 380 425 3000 8 lxk9-pw30-0008 350 90 93 660 735 830 3000 12 lxk9-pw30-0012 350 90 93 1010 1100 1250 3000 16 lxk9-pw30-0016 350 90 93 1350 1465 1665 3000 24 lxk9-pw30-0024 350 90 93 2045 2145 2450 2700 ** 4 lxk8-pw27-0004 350 80 83 310 375 430 2700 ** 8 lxk8-pw27-0008 350 80 83 680 775 890 2700 ** 12 lxk8-pw27-0012 350 80 83 990 1165 1330 2700 ** 16 lxk8-pw27-0016 350 80 83 1380 1595 1830 2700 ** 24 lxk8-pw27-0024 350 80 83 1960 2400 2730 3000 ** 4 lxk8-pw30-0004 350 80 83 330 430 480 3000 ** 8 lxk8-pw30-0008 350 80 83 730 855 980 3000 ** 12 lxk8-pw30-0012 350 80 83 1070 1280 1460 3000 ** 16 lxk8-pw30-0016 350 80 83 1475 1780 1990 3000 ** 24 lxk8-pw30-0024 350 80 83 2100 2495 2850 4000 ** 4 lxk8-pw40-0004 350 80 83 380 480 540 4000 ** 8 lxk8-pw40-0008 350 80 83 780 950 1080 4000 ** 12 lxk8-pw40-0012 350 80 83 1120 1430 1610 4000 ** 16 lxk8-pw40-0016 350 80 83 1590 1925 2180 4000 ** 24 lxk8-pw40-0024 350 80 83 2260 2980 3340 notes for table 1: 1. lumileds maintains a tolerance of 6.5% on luminous fux and 2 on cri measurements. 2. * = high voltage multi-junction. 3. ** = parts with original fux performance (before fux upgrade). product selection guide for luxeon k royal blue, junction temperature = 85c, test current = 350ma table 2. color emitter count part number minimum radiometric power (mw) typical radiometric power (mw) maximum radiometric power (mw) typical radiant efciency (%) royal blue 8 lxk0-pr04-0008 4500 4670 5400 62% royal blue 16 lxk0-pr04-0016 9000 9350 10800 62% no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 5 optical characteristics luxeon k white at test current, junction temperature = 85c table 3. part number nominal cct color temperature cct typical total included angle [2] (degrees) u 90v typical viewing angle [2] (degrees) 2 u ? typical lxkx-pw27-xxxx(a) 2700k 2725k 125 100 lxkx-pw30-xxxx(a) 3000k 3045k 125 100 lxkx-pw35-xxxx 3500k 3465k 125 100 lxkx-pw40-xxxx(a) 4000k 3985k 125 100 lxkx-pw50-xxxx 5000k 5028k 125 100 notes for table 3: 1. total angle at which 90% of total luminous fux is captured. 2. viewing angle is the of axis angle from lamp centerline where the luminous intensity is ? of the peak value. luxeon k royal blue (lxk0-prxx) at test current [1] , junction temperature = 85c table 4. part color peak wavelength, l p [2] typical spectral half-width (nm) [3] dl 1/2 typical temp coefcient of peak wavelength (nm/c) dl 1/2 typical total included angle [4] (degrees) u 90v typical viewing angle [5] (degrees) 2 u ? min typ max royal blue 447.5nm 450nm 452.5nm 20 0.05 140 116 notes for table 4: 1. test current is 350ma for all lxk0-prxx products. 2. royal blue product has single peak wavelength bin. 3. spectral half-width is ? of the peak intensity. 4. total included angle at which 90% of total radiometric power is captured. 5. viewing angle is the of-axis angle from lamp centerline where the luminous intensity is ? of the peak value. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 6 electrical characteristics electrical characteristics at test current for luxeon k white and royal blue, junction temperature = 85c table 5. part number forward voltage v f [1] (v) typical temperature coefcient of forward voltage (mv/c) d v f / d t j typical thermal resistance junction to case (c/w) r u j-c minimum typical maximum lxkx-pxxx-0403 30 31.5 33.8 -21.0 5.5 lxkx-pxxx-xx04(a) 10 10.5 11.3 -6.3 3.0 lxkx-pxxx-x404 40 42 45.1 -30.1 3.0 lxkx-pxxx-xx08(a) 20 21 22.6 -12.5 1.5 lxkx-pxxx-x206 30 31.5 33.8 -21.0 2.3 lxkx-pxxx-xx12(a) 30 31.5 33.8 -18.8 1.0 lxkx-pxxx-xx16(a) 40 42 45.1 -25.0 0.8 lxkx-pxxx-xx24(a) 60 63 67.7 -37.5 0.5 notes for table 5: 1. lumlileds maintains a tester tolerance of 0.5% on forward voltage measurements. 2. junction temperature to back of the pcb. typical electrical characteristics at twice the test current for luxeon k white and royal blue, junction temperature = 85c table 6. part number typical forward voltage v f (v) test current (ma) lxkx-pxxx-x403 36 87.5 lxkx-pxxx-xx04(a) 11 350 lxkx-pxxx-x404 48 87.5 lxkx-pxxx-xx08(a) 22 350 lxkx-pxxx-x206 36 175 lxkx-pxxx-xx12(a) 33 350 lxkx-pxxx-xx16(a) 44 350 lxkx-pxxx-xx24(a) 66 350 no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 7 absolute maximum ratings table 7. parameter maximum performance lxkx-pxxx-x004/x006/x008/ x012/x016/x024 lxkx-pxxx-x403/x404 lxkx-pxxx-x206 dc forward current (ma) 1050 300 600 peak pulsed forward current (ma) 1050 300 600 esd sensitivity < 8000v human body model (hbm) class 3a jesd22-a114-e < 400v machine model (mm) class b jesd22-a115-b led junction temperature [1] 125c operating case temperature -40c - 125c storage temperature -40c - 125c reverse voltage (v r ) see note 2 notes for table 7: 1. proper current derating must be observed to maintain junction temperature below the maximum. 2. luxeon power leds are not designed to be driven in reverse bias. electrical lead soldering characteristics please refer to application brief ab102 for luxeon k. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 8 mechanical dimensions lxkx-pxxx-xxx3 notes for figure 1: 1. all dimensions are in millimeters. figure 1. dimensions for lxkx-pxxx-xxx3. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 9 lxkx-pxxx-xxx4(a) notes for figure 2: 1. all dimensions are in millimeters. 3 . 3 0 dome p itc h 1 . 6 5 3.30 dome pitch 1.6 5 3 . 6 2 3 . 2 2 1.50 (2plcs) 0.31 (2plcs) 45.0 17. 4 7 2.86 (2plcs) 17. 6 7 5. 4 6 ( 2 p lcs) 0 . 50 1 . 90 45.0 3 . 4 5 5.59 3.45 1 . 045 b oard t h ic k n e s s 1 . 265 r 1 . 50 ( 4 p lcs) 0 . 7 6 silic on e h e ig h t f rom p cb s u rf ac e 2 d ba rco d e r 1 ( 2 p lcs) r 1 ( 2 p lcs) 3 . 3 0 wire s lot ( 2 p lcs) a 0 . 50 max. ru nne r h e ig h t f rom p cb s u rf ac e b a 19.15 3 (2plcs) 8.50 (2plcs) 18.85 ( 2 p lcs) 6 . 2 5 ( 2 p lcs) 5.72 (2plcs) 7.50 (2plcs) 2 (2plcs) 6 . 2 5 ( 2 p lcs) 1 . 50 2 . 10 9 . 40 r 0 . 50 d e ta il b 6 . 90 r 0 . 50 ( 5p lcs) 6 .90 r 1 ( 2 x ) d e ta il a s c a l e 10 : 1 ( 2 p lcs) 2 . 2 0 2 . 4 0 ( 2 p lcs) 3 . 4 0 3 . 2 0 1 figure 2. dimensions for lxkx-pxxx-xxx4(a). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 10 lxkx-pxxx-xxx6 notes for figure 3: 1. all dimensions are in millimeters. figure 3. dimensions for lxkx-pxxx-xxx6. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 11 lxkx-pxxx-xx08(a) notes for figure 4: 1. all dimensions are in millimeters. 7 . 13 ( 2 p lcs) 0 . 1 5 ( 2 p lcs) 1.50 (2plcs) 2.80 (2plcs) 45.0 4 5. 0 51 . 43 dome array ( 7 x ) 0 . 64 2 . 4 5 3 . 6 2 3 . 2 2 b a (2plcs) 10.95 (2plcs) 21.6 5 3 (2plcs) 9.95 1 . 50 ( 2 p lcs) 22. 3 5 22. 6 5 ( 2 p lcs) 8 . 9 8 2 ( 2 p lcs) 21.35 5.77 (2plcs) 10 9.75 5.6 0 (2plcs) 10.75 21.75 21.25 2d bar c ode ( 2 p lcs) r 1 r 1 ( 2 p lcs) 3 . 3 0 wire s lot ( 2 p lcs) d e ta il b 5. 6 5 5. 53 5. 43 5. 46 3 . 8 5 3 . 87 d e ta il a s c a l e 8 : 1 2 1 2 . 3 5 2 . 2 5 4 . 60 ( 2 p lcs) 3 . 3 5 3 . 2 5 ( 2 p lcs) 1 . 265 1 . 045 b oard t h ic k n e s s r 1 . 50 ( 8 p lcs) 0 . 7 6 silic on e h e ig h t f rom p cb s u rf ac e a 0 . 50 max. ru nne r h e ig h t f rom p cb s u rf ac e figure 4. dimensions for lxkx-pxxx-xxx8(a). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 12 lxkx-pxxx-xx12(a) notes for figure 5: 1. all dimensions are in millimeters. 3.30 (3plcs) dome pitch 1.6 5 3 . 6 2 3 . 2 2 6 . 7 5 4 5. 0 8 . 37 ( 2 p lcs) 2.80 (2plcs) 1.50 (2plcs) 0 . 80 ( 2 p lcs) 3 . 30 ( 3 p lcs) dome p itc h 1 . 6 5 a 0 . 50 max. ru nne r h e ig h t f rom p cb s u rf ac e ch a mf er ( 4 p l cs ) d e ta il b 3 . 35 x 4 5 13. 50 6 . 7 5 13. 50 r 1 ( 8 x ) d e ta il a s c a l e 8 : 1 5. 80 3 . 2 5 2 1 3 . 3 5 ( 2 p lcs) 2 . 3 5 2 . 2 5 ( 2 p lcs) b a 2 (2plcs) 10.90 1 . 50 ( 2 p lcs) 24.45 11.10 3 (2plcs) 2 5. 1 5 24. 8 5 12.10 4.6 3 (2plcs) 10.70 23.95 10. 97 ( 2 p lcs) 5.6 0 (2plcs) (2plcs) 6 (2plcs) 11.90 24.35 24.05 2d bar c ode r1 (2plcs) r 1 ( 2 p lcs) 3.30 wire s lot (2plcs) r 1 . 50 ( 12p lcs) 1 . 265 1 . 045 b oard t h ic k n e s s 0 . 7 6 silic on e h e ig h t f rom p cb s u rf ac e figure 5. dimensions for lxkx-pxxx-xx12(a). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 13 lxkx-pxxx-xx16(a) notes for figure 6: 1. all dimensions are in millimeters. 3.30 (3plcs) do me pi t ch 1.6 5 3.30 (3plcs) dome pitch 1.6 5 3.6 2 3.22 45.0 1.50 (2plcs) 2.80 (2plcs) 8.37 (2plcs) 2 (2plcs) 0.80 (2plcs) 1.26 5 1.045 bo ar d thi ck nes s r1.50 (16plcs) 0.76 si lico ne hei ght f r o m pcb s ur f ace a 0.50 max. r unner hei ght f r o m pcb s ur f ace a b 25.15 5.6 0 (2plcs) 6 (2plcs) 10.90 (2plcs) 11.90 3 (2plcs) 24.35 24.85 24.05 24.45 10.70 (2plcs) 11.10 4.6 3 (2plcs) 10.97 23.95 12.10 1.50 (2plcs) d e ta il a s c a l e 8 : 1 2 (2plcs) 3.25 3.35 2.35 2.25 (2plcs) 1 5.80 d e ta il b s c a l e 4 : 1 6 .75 0.97 1.92 13.50 6 .75 13.50 2.20 r0.70 (4plcs) 2 d b a r c od e 3.30 wire s lot (2plcs) r1 (2plcs) r1 (2plcs) figure 6. dimensions for lxkx-pxxx-xx16(a). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 14 lxkx-pxxx-xx24(a) notes for figure 7: 1. all dimensions are in millimeters. 3 .6 2 3 .2 2 12.27 (4plcs) 11.8 4 (4 pl c s) 10 (2plcs) 5 .3 3 (2 pl c s) 15 9 .1 5 1 .5 0 (2 x) 8 .2 0 (2 x) 4.90 4.70 (4plcs) 15 13.4 0 13.2 0 (4 pl c s) 14.4 0 14.2 0 (4 pl c s) 15 2d bar c ode a 7 (2x) 2.333 (2x) 4.667 (2x) 0 .5 0 ma x. r unne r he i ght f r om pc b s ur f a ce ( 2x ) 3 . 6 mm x 4 5 c h a m fe r c 1. 1 x 45 c 1 . 1 x 4 5 a 3 (2 x) 29.75 r 1 .5 0 (2 pl c s) 2 (2 pl c s) 18.30 18.3 0 r 4 .0 5 (3 x) 1 .5 0 (2 pl c s) 1.35 (2x) 30.25 30.1 5 29.8 5 r 0 .7 5 1 .0 4 5 b oa r d t hi ck ne s s 1 .2 6 5 7 (2 x) (2 4 pl c s) r 1 .5 0 2 .3 33 (2 x) 4 .6 67 (2 x) 0.76 si lic on e h ei gh t f r om p cb sur f ac e d e ta il a s c a l e 6 : 1 2 .3 5 r 1 2 .0 5 1 .3 5 (4 pl c s) (4plcs) r1 (4plcs) 1 .1 5 r1 3 .3 5 3 .2 5 (4 pl c s) 2 .2 5 r 1 .2 0 0 .3 5 1 r1.6 5 (4plcs) wire s lot figure 7. dimensions for lxkx-pxxx-xx24(a). no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 15 relative spectral distribution vs. wavelength characteristics lxk8-pwxx-xxxx at test current, junction temperature = 85c lxk0-pr04-xxxx (royal blue) at test current, junction temperature = 85c figure 8. color spectrum of lxk8-pwxx-xxxx product, integrated measurement. figure 9. color spectrum of lxk0-pr04-xxxx product, integrated measurement. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 16 light output characteristics over temperature all luxeon k products at test current, normalized at test current, junction temperature = 85c figure 10. typical relative fux vs. junction temperature at test current. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 17 typical forward current characteristics typical forward current vs. forward voltage luxeon k 3-up products, junction temperature = 85c typical forward current vs. forward voltage luxeon k 4-up products, junction temperature = 85c note for figure 12: 1. luxeon lxkx-pxxx-0004(a) is single junction product. figure 11. forward current vs. forward voltage for lxkx-pxxx-x403 products. figure 12. forward current vs. forward voltage for lxkx-pxxx-0004(a) products. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 18 typical forward current vs. forward voltage luxeon k 4-up high-voltage products, junction temperature = 85c typical forward current vs. forward voltage luxeon k 6-up high-voltage products, junction temperature = 85c figure 13. forward current vs. forward voltage for lxkx-pxxx-x404 products. figure 14. forward current vs. forward voltage for lxkx-pxxx-x206 products. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 19 typical forward current vs. forward voltage luxeon k 8-up products, junction temperature = 85c typical forward current vs. forward voltage luxeon k 12-up products, junction temperature = 85c figure 15. forward current vs. forward voltage for lxkx-pxxx-xxx8(a) products. figure 16. forward current vs. forward voltage for lxkx-pxxx-xx12(a) products. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 20 typical forward current vs. forward voltage luxeon k 16-up products, junction temperature = 85c typical forward current vs. forward voltage luxeon k 24-up products, junction temperature = 85c figure 17. forward current vs. forward voltage for lxkx-pxxx-xx16(a) products. figure 18. forward current vs. forward voltage for lxkx-pxxx-xx24(a) products. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 21 typical relative luminous flus vs. forward current for all luxeon k product confgurations without multi-junction die, junction temperature 85c typical relative luminous flus vs. forward current for all luxeon k product confgurations with multi-junction die, junction temperature 85c figure 19. typical relative luminous fux vs. forward current. 0.4 0.6 0.8 1.0 1.2 d c forward current (a) r j-air = 2c/w r j-air = 4c/w r j-air = 6c/w r j-air = 8c/w r j-air = 10c/w 0.0 0.2 0 20 40 60 80 100 120 140 maximum d ambient temperature (c) figure 20. typical relative luminous fux vs. forward current for luxeon k (lxkx-pwxx-0206) with multi-junction die. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 22 typical relative luminous flus vs. forward current for luxeon k lxkx-pwxx-0403/lxkx-pwxx-0404 product confgurations with multi-junction die, junction temperature 85c figure 21. typical relative luminous fux vs. forward current for luxeon k (lxkx-pwxx-0403/lxkx-pwxx-0404) with multi-junction die. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 23 typical radiation patterns typical spatial radiation pattern for luxeon k packaging on trays luxeon k products will be securely packaged in trays. table 8. part number tray dimensions quantity per tray number of trays per box lxkx-pxxx-xxx3 lxkx-pxxx-xxx4(a) 315mm width x 135.9mm length x 12.11mm depth 40 10 lxkx-pxxx-xxx6 lxkx-pxxx-xxx8(a) 315mm width x 135.9mm length x 12.11mm depth 27 10 lxkx-pxxx-xx12(a) lxkx-pxxx-xx16(a) 315mm width x 135.9mm length x 12.11mm depth 24 10 lxkx-pxxx-xx24 315mm width x 135.9mm length x 12.11mm depth 21 10 0 20 40 60 80 100 120 -90 -75 -60 -45 -30 -15 0 15 30 45 60 75 90 relative intensity (%) angular displacement (degrees) figure 22. typical representative spatial radiation pattern for luxeon k. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 24 tray dimensions C lxkx-pxxx-xxx3 and lxkx-pxxx-xxx4(a) tray dimensions C lxkx-pxxx-xxx6 and lxkx-pxxx-xxx8(a) figure 23. figure 24. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 25 tray dimensions C lxkx-pxxx-xx12(a) and lxkx-pxxx-xx16(a) tray dimensions C lxkx-pxxx-xx24(a) figure 25. figure 26. no longer orderable
DS102 luxeon k product datasheet 20160726 ?2016 lumileds holding b.v. all rights reserved. 26 luxeon k white ansi color bin defnition table 9. luxeon k 3-step macadams ellipse color defnition nominal ansi cct 2700k 3000k 3500k 4000k 5000k single 3-step macadam ellipse single 3-step macadam ellipse single 3-step macadam ellipse single 3-step macadam ellipse single 3-step macadam ellipse center point (cx, cy) [1] (0.4578, 0.4101 ) (0.4338, 0.4030) (0.4073, 0.3917) (0.3818, 0.3797) (0.3447, 0.3553) major axis, a 0.0081 0.00834 0.00927 0.00939 0.00822 minor axis, b 0.0042 0.00408 0.00414 0.00402 0.00354 ellipse rotation angle 53.7 53.22 54.00 53.72 59.62 note for table 9: 1. lumileds maintains a tester tolerance of 0.005 on x, y color coordinates. 0.420 0.440 2700k ansi 3000k ansi 3500k ansi blackbody locus 0.380 0.400 0.420 e 1931 y 3000k ansi 3500k ansi 4000k ansi blackbody locus 0.340 0.360 0.380 cie 1931 y 2700k 3-step macadams ellipse 3000k 3-ste p macadams elli p se 5000k ansi 0.320 0.340 0.320 0.340 0.360 0.380 0.400 0.420 0.440 0.460 0.480 0.500 cie 1931 x 2700k 3-step macadams ellipse 3000k 3-step macadams ellipse 3500k 3-step macadams ellipse 4000k 3-step macadams ellipse 5000k 3-step macadams ellipse 0 . 320 0 . 340 0 . 360 0 . 380 0 . 400 0 . 420 0 . 440 0 . 460 0 . 480 0 . 500 cie 1931 x figure 27. graph of luxeon k ansi bin color defnition. no longer orderable
?2016 lumileds holding b.v. all rights reserved. luxeon is a registered trademark of the lumileds holding b.v. in the united states and other countries. lumileds.com about lumileds lumileds is the global leader in light engine technology. the company develops, manufactures and distributes groundbreaking leds and automotive lighting products that shatter the status quo and help customers gain and maintain a competitive edge. with a rich history of industry frsts, lumileds is uniquely positioned to deliver lighting advancements well into the future by maintaining an unwavering focus on quality, innovation and reliability. to learn more about our portfolio of light engines, visit lumileds.com . DS102 luxeon k product datasheet 20160728 neither lumileds holding b.v. nor its afliates shall be liable for any kind of loss of data or any other damages, direct, indirect or consequential, resulting from the use of the provided information and data. although lumileds holding b.v. and/or its afliates have attempted to provide the most accurate information and data, the materials and services information and data are provided as is, and neither lumileds holding b.v. nor its afliates warrants or guarantees the contents and correctness of the provided information and data. lumileds holding b.v. and its afliates reserve the right to make changes without notice. you as user agree to this disclaimer and user agreement with the download or use of the provided materials, information and data. no longer orderable